If you are interested in solar collector sets that will enable you to limit heating costs in summer period up to 90% and annually up to 60%, please contact.
Within 24 hours we will send you results, selection suggestions and simulations of possible financial and ecological effects.
Enameled containers and buffer containers
Within 24 hours we will send you results, selection suggestions and simulations of possible financial and ecological effects.
Enameled containers and buffer containers
|
Solar water heater FISH S 1 – Single coil pipe solar heaters FISH S1 are manufactured in volumes from 150 to 2000 l. Long life of containers is guaranteed by anticorrosive protection in form of enamel layer and magnesium anode. |
||||||
| Dimensions (mm) | |||||||
| Type | Catalog number | Volume (L) | Height | Diameter | Coil pipe m2 |
||
| FISH 150 S1 |
- |
150 |
1070 |
555 |
0,74 | ||
| FISH 400 S1 |
- |
400 |
1460 |
750 |
1,7 |
||
| FISH 2000 S1 |
- |
2000 |
2310 |
1350 |
4,0 |
||
| Full assortment of containers is available in catalog. | |||||||
|
Solar water heater FISH S2 - Double coil pipe solar heaters FISH S2 are manufactured in volumes from 150 to 2000 l. Long life of containers is guaranteed by anticorrosive protection in form of enamel layer and magnesium anode.
|
||||||
| Dimensions (mm) | Coil pipe m2 |
||||||
| Type | Catalog number | Volume (L) |
Height | Diameter | top | bottom | |
| FISH 150 S2 | - | 150 | 1070 | 555 | 0,6 | 0,4 | |
| FISH 400 S2 | - | 400 | 1460 | 750 | 1,5 | 1,0 | |
| FISH 2000 S2 | - | 2000 | 2310 | 1350 | 4,0 | 3,0 | |
| Full assortment of containers is available in catalog. | |||||||
![]() |
Multivalent containers FISH S 3 – Accumulators enable buffering of heat in heating installation and simultaneous warm water preparation. Due to construction “container in container” rapid and permanent water heating in internal enameled container takes place. Containers are insulated with soft polyurethan foam 100 mm. | ||||||
| Dimensions (mm) | |||||||
| Type | Catalog number | Volume (L) |
Height | Diameter | Coil pipe m2 |
||
| FISH 600 S3 | - | 600 | 1870 | 850 | 1,7 | ||
| FISH 800 S3 | - | 800 | 1910 | 900 | 2,9 | ||
| FISH 1000 S3 | - | 1000 | 2090 | 900 | 3 | ||
| FISH 1500 S3 | - | 1500 | 2200 | 1200 | 3,4 | ||
![]() |
Buffer containers FISH S4 i S5 – Buffer tanks without coil pipe (FISH S4) or with one solar coil pipe (FISH S5) are manufactured in volumes from 500 to 2000 l. By means of these containers it is possible to buffer the heat in heating installation and in case of buffer with coil pipe supporting central heating installation directly from solar installation, without necessity of additional heat exchanger.
|
||||||
| Dimensions (mm) | |||||||
| Type | Catalog number | Volume (L) |
Height | Diameter | Coil pipe m2 |
||
| FISH S4/S5 |
- |
500 |
1610 |
850 |
1,7 |
||
| FISH S4/S5 | - |
800 |
1860 |
990 |
2,9 |
||
| FISH S4/S5 | - |
1000 |
2040 |
990 |
3 |
||
| FISH S4/S5 | - |
1500 |
2170 |
1200 |
3,4 |
||
| FISH S4/S5 | - | 2000 | 2200 | 1350 | 4 | ||
![]() |
Solar tank hydroUnit – Tank with optimal anticorrosive protection in form of enamel according to DIN 4753, with built-in anode and two permanently assembled coil pipes of large surface 1''. The container is equipped with pump and controller. | ||||||
| Dimensions (mm) |
Coil pipe m2 |
||||||
| Catalog number | Volume (L) |
Height | Diameter | inclined | bottom | top | |
| - |
300 |
1790 |
600 |
1860 |
1,4 |
1,0 |
|
| - |
400 |
1835 |
670 |
1930 |
1,8 |
1,0 |
|
| - |
500 |
1853 |
750 |
1970 |
2,0 |
1,0 |
|
![]() |
Solar tank hydroSmalt RR – Tank with optimal anticorrosive protection in form of enamel according to DIN 4753, with built-in anode and two permanently assembled coil pipes. | ||||||
| Solar tank hydroSmalt RR with two coil pipes | |||||||
| Dimensions (mm) | Coil pipe m2 |
||||||
| Catalog number | Volume (L) |
Height | Diameter | inclined | bottom | top | |
| - |
300 |
1790 |
600 |
1860 |
1,4 |
1,0 |
|
| - |
400 |
1835 |
670 |
1930 |
1,8 |
1,0 |
|
| - |
500 |
1853 |
750 |
1970 |
2,0 |
1,0 |
|
| Solar container hydroSmalt R with one coil pipe | |||||||
| - |
200 |
1340 |
600 |
1394 |
1,0 |
||
| - |
300 |
1790 |
600 |
1860 |
1,4 |
||
| - |
500 |
1853 |
750 |
1970 |
2,0 |
||
![]() |
Multi-purpose tank of large volume - Tank with optimal anticorrosive protection in form of enamel according to DIN 4753, with built-in magnesium anode, working pressure 6 bar. Code: FFM with 2 flanges, FRM with 1 coil pipe permanently assembled, | ||||||
| Catalog number Type |
Volume (L) |
Dimensions (mm) |
Kołnierz 240mm | Coil pipe m2 |
|||
| Height | No ins. in. | bottom |
top |
||||
| VT-N working pressure 6 bar |
|||||||
| VT-N FFM | 800 | 2000 | 790 | 2 szt. | - | - | |
| VT-N FRM |
800 |
2000 |
790 |
1 szt. |
2,0 |
- |
|
| VT-S FRM |
1000 | 2350 | 790 |
1 szt. | 3,51 | - | |
| Full assortment of containers is available in catalog. | |||||||
|
Buffer tank - Tank GK-PSM made of steel metal sheets ST 37.2, ground coated outside, with all couplings 6/4" IG and 1/2" IG, working pressure 3 bar max. working temp. 95oC. Code: GK-PSR as in container GK-PSM, but with flange with diameter 300mm/width in light 210mm with screws, nuts and seals – without plug plate, GK-PSRR as GK-PSM, but with permanently built-in coil pipe 1" with large heating surface. | ||||||
| Catalog number Type | Volume (L) |
Dimensions (mm) |
Coil pipe m2 |
||||
| Height | Diameter | inclined | top |
bottom | |||
| GK-PSM |
500 |
1640 |
650 |
1700 |
- |
- |
|
| GK-PSR |
500 |
1640 |
650 |
1700 |
- |
1,8 |
|
| GK-PSRR |
1000 |
2050 |
790 |
2100 |
2,4 |
3,0 |
|
| Full assortment of containers is available in catalog. | |||||||
| Buffor combi – type tank - Tank GK-KS made of steel metal sheets ST 37.2, ground coated outside, with all couplings 6/4" IG and 1/2" IG, working pressure 3 bar max. working temp. 95oC, with built-in solar coil pipe from pipe radiator 1". | |||||||
| Catalog number Type | Volume (L) |
Dimensions (mm) | Coil pipe m2 |
||||
| Height | Diameter | inclined | bottom | ||||
| GK-KS |
500 |
1695 |
650 |
1700 |
1,9 |
||
| GK-KS |
1000 |
2105 |
790 |
2150 |
3,0 |
||
| GK-KS |
2000 |
2425 |
1100 |
2520 |
4,2 |
||
| Full assortment of containers is available in catalog. | |||||||
|
Hygienic stratified storage tank hyGenio – combi-type tank for hygienic water heating during flow. Buffer tank made of steel sheets ST.37.2, ground coated outside, with all couplings, working pressure 3 bar, max. working temp. 95oC. Flow heat exchanger of large volume made of stainless steel, max 6 bar. |
||||||
| with one solar coil pipe made of steel pipe 1" |
|||||||
| Catalog number Type |
Warm water coil pipe | Dimensions (mm) |
Coil pipe m2 |
||||
| Height | inclined | Diameter | top | bottom | |||
| GK-HGR 600 |
38 l |
1640 |
1740 |
700 |
- |
1,8 |
|
| GK-HGR 1000 |
58 l |
2050 |
2150 |
790 |
- |
3,0 |
|
| GK-HGR 1500 |
76 l |
2150 |
2270 |
1000 |
- |
3,6 |
|
| with two solar coil pipe made of steel pipe 1" | |||||||
| GK-HGRR 600 |
38 l |
1640 |
1740 | 700 | 1,2 | 1,8 | |
| GK-HGRR 1000 |
58 l | 2050 | 2150 | 790 | 2,4 | 3,0 | |
| GK-HGRR 1500 |
76 l | 2150 | 2270 | 1000 | 2,4 | 3,6 | |
| Full assortment of containers is available in catalog. | |||||||